DORMO® LF-50 ECG Electrode Ø50 mm – Semi-liquid gel for cardiac monitoring
DORMO® LF-50 ECG Electrode Ø50 mm – Semi-liquid gel for cardiac monitoring
Dormo KFS-140 ECG electrode - Ø25 mm
Dormo KFS-140 ECG electrode - Ø25 mm

DORMO LEH-36 ECG Electrode – 36 x 50 mm for Stress Testing

€0.13 VAT included

The DORMO LEH-36 ECG Electrode is a disposable Ag/AgCl electrode specifically designed for cardiac monitoring during stress tests in adult patients.

It features a waterproof flexible polyethylene foam backing, acrylic adhesive and a water-soluble semi-liquid acrylic gel, helping provide stable contact between the skin and the electrode during ECG recording.

The DORMO Ag/AgCl range complies with the electrical safety requirements of ANSI/AAMI EC12 and can remain applied to the patient for up to 24 hours.

  • Ag/AgCl ECG electrode
  • Reference: LEH-36 / TEDS1
  • Size: 50 ± 1 x 36 ± 1 mm
  • Specifically designed for stress testing
  • For adult patients
  • Waterproof flexible PE foam backing
  • Acrylic adhesive
  • Water-soluble semi-liquid acrylic gel
  • Stainless steel/plastic Ag/AgCl-coated sensor
  • PET protective liner
  • Biocompatible
  • Latex-free
  • Non-sterile
  • Single-use
  • Maximum application time: 24 hours
  • Shelf life: 3 years
  • 50 units per pouch
  • 20 pouches per case
  • 1,000 units per service case

Practical applications

Stress testing

  • Specifically designed for ECG monitoring during stress tests
  • Suitable for adult patients

Cardiac monitoring

  • Detects small electrical impulses produced during each heartbeat
  • Suitable for ECG recording for up to 24 hours

Professional use

  • Waterproof backing is practical in situations involving movement or perspiration
  • Semi-liquid gel supports effective electrical contact with the skin

Frequently Asked Questions (FAQs)

Is it specifically designed for stress testing?
Yes. The technical sheet explicitly states that the LEH-36 is designed for stress tests.

How long can it remain on the patient?
DORMO Ag/AgCl ECG electrodes can remain applied for up to 24 hours.

What type of gel does it use?
It uses a water-soluble semi-liquid acrylic gel absorbed into polyester foam.

Is it biocompatible?
Yes. It has been tested according to ISO 10993-5 and ISO 10993-10, with non-cytotoxic, non-sensitising and negative intracutaneous irritation results.

Does it contain latex?
No. It is latex-free.

Is it sterile?
No. It is a non-sterile product.

Does it meet ECG electrical safety requirements?
Yes. It meets the requirements of ANSI/AAMI EC12.

How many units are supplied per case?
TEDS1 is supplied as 50 electrodes per pouch, 20 pouches per case, 1,000 electrodes in total.

DORMO / Telic Trust – ECG monitoring for stress testing

  • Class I medical device
  • Compliant with Regulation (EU) 2017/745
  • Manufactured under an ISO 13485 certified quality system
  • Meets ANSI/AAMI EC12 electrical requirements
  • Biocompatibility according to ISO 10993
  • Latex-free
  • GMDN 35035
  • EMDN C020501
  • Manufactured by Telic, S.A.U., Spain
Availability: In stock
SKU
TEDS1
Medical device for professional use. Its purchase implies a declaration of responsibility confirming that the user is a healthcare professional.
DORMO LEH-36 ECG Electrode – 36 x 50 mm for Stress Testing is available to buy in increments of 1000
Technical characteristics
Patient Adult
Application Stress / Holter
Connection Stud
Gel Semiliquid
Radiotransparent No
Backing Foam
Class I
Units per pouch 50
Units per box 1000
Dimensions 36 x 50 mm

Do you have questions or want information about a product? Leave us your message and we will contact you to solve it.